Pomiń, aby przejść do informacji o produkcie
1 z 1

Isolating switch F200 3x40A IP66 1NO/1NC

KEA 363 FR1V A4

Isolating switch F200 3x40A IP66 1NO/1NC

Katko firerated isolators (16-800A) are designed to maintain circuit integrity and isolation functionality even under fire exposure. They support safety-critical installations where continued performance during extreme conditions is required.

Built with durable materials and tested to meet relevant fire performance standards, they provide dependable isolation for public buildings, infrastructure, and industrial facilities.

GTIN
6419410335918
Rated operational current AC-23A 415V (A)
40
Enclosure type
Aluminium
Enclosure
A4 (162 x 262 x 108 mm)
Firerated
F200
Pokaż kompletne dane

Product details and documents

Technical data

Depth
108 mm
EMC
false
Enclosure
A4 (162 x 262 x 108 mm)
Enclosure type
Aluminium
ETIM Class
EC000216
Firerated
F200
GTIN
6419410335918
Height
262 mm
IP rating
IP66
Long product name
3-pole, Auxiliary contact 1NO/1NC, Heat-resistant; F200 200°C/3h EN 12101-3, Aluminum enclosure; W162 x H262 x D108
Max. term. torque (Nm)
2.5
Mech. endurance (no. of oper.)
50000
Net weight
2.5789 kg
Nom. values w/cable size (mm²)
25
Number of poles
3
Product type
KEA 363 FR1V A4
Rated breaking cap. ICN AC-23A 415V (A)
320
Rated breaking cap. ICN AC-23A 500V (A)
320
Rated breaking cap. ICN AC-23A 690V (A)
320
Rated fused short-ckt current back-up fuse opt 1 (A)
80
Rated fused short-ckt current peak value (kA)
8.2
Rated fused short-ckt current RMS Ik opt 1 (kA)
50
Rated fused short-ckt. impulse withstand volt. Uimp (kV)
8
Rated insulation volt. Ui (V)
800
Rated operational current AC-21A 415V (A)
80
Rated operational current AC-21A 500V (A)
80
Rated operational current AC-21A 690V (A)
80
Rated operational current AC-22A 415V (A)
63
Rated operational current AC-22A 500V (A)
63
Rated operational current AC-22A 690V (A)
63
Rated operational current AC-23A 415V (A)
40
Rated operational current AC-23A 500V (A)
40
Rated operational current AC-23A 690V (A)
40
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 415V (kW)
22
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 500V (kW)
30
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 690V (kW)
37
Rated short-ckt. making cap. Icm 690V (kA)
3.1
Rated short-time withstand current 1s Icw 690V (kA)
2
Rated therm. current Ithe (A)
80
Rated therm. current Ith (A)
80
Short product description
Isolating switch F200 3x40A IP66 1NO/1NC
Switch type
Load Break Switch
Technical name
3x40A 400V 22kW
Terminals bolt size (Cu mm²)
2.5..35
Volume
4.584 l
Width
162 mm

Dimensional drawing

Logistical data

Package size 1
1
Sales unit
1