Katko LoadSafe load break switches 160–800A are high-capacity solutions built for demanding industrial and power distribution networks up to 800 A. They support heavy-duty load switching, motor isolation and backup power transfer applications. These switches are engineered for reliability and durability, ensuring dependable operation where continuity and performance matter most.
E-number FI
GTIN
6419410205280
Rated operational current AC-22A 415V (A)
250
Rated operational current AC-22A 690V (A)
250
Product details and documents
Technical data
Depth
150 mm
ETIM Class
EC000216
E-number FI
3602993
GTIN
6419410205280
Height
163 mm
Long product name
Rotary switch, Changeover switch with 1-0-2 positions, 3-pole, Includes shaft 200 mm, Handle
Max. term. torque (Nm)
15..22
Mech. endurance (no. of oper.)
16000
Net weight
1.21 kg
Nom. values w/cable size (mm²)
120
Number of poles
3
Product type
KU 3250WCO L200AD12T6LKX100
Rated breaking cap. ICN AC-23A 415V (A)
2000
Rated breaking cap. ICN AC-23A 500V (A)
2000
Rated breaking cap. ICN AC-23A 690V (A)
2000
Rated fused short-ckt current back-up fuse opt 1 (A)
250
Rated fused short-ckt current back-up fuse opt 2 (A)
315
Rated fused short-ckt current peak value (kA)
26
Rated fused short-ckt current RMS Ik opt 1 (kA)
100
Rated fused short-ckt current RMS Ik opt 2 (kA)
50
Rated fused short-ckt. impulse withstand volt. Uimp (kV)
12
Rated insulation volt. Ui (V)
1000
Rated operational current AC-21A 415V (A)
250
Rated operational current AC-21A 500V (A)
250
Rated operational current AC-21A 690V (A)
250
Rated operational current AC-22A 415V (A)
250
Rated operational current AC-22A 500V (A)
250
Rated operational current AC-22A 690V (A)
250
Rated operational current AC-22A 800V (A)
250
Rated operational current AC-23A 1000V (A)
135
Rated operational current AC-23A 415V (A)
250
Rated operational current AC-23A 500V (A)
250
Rated operational current AC-23A 690V (A)
250
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 415V (kW)
132
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 500V (kW)
160
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 690V (kW)
250
Rated short-ckt. making cap. Icm 690V (kA)
14
Rated short-time withstand current 1s Icw 1000V (kA)
8
Rated therm. current Ith (A)
315
Short product description
Change-over switch 1-0-2 3x250A
Switch type
Load Break Switch
Technical name
3x250A 690V AC-22
Terminals bolt size (Cu mm²)
M8
Volume
3.8387 l
Width
157 mm
No dimensional drawings available for this product.
Dimensional drawing
No dimensional drawings available for this product.
Logistical data
Package size 1
1
Package size 1 depth
150 mm
Package size 1 GTIN code
6419410205280
Package size 1 height
163 mm
Package size 1 volume
3.6675 l
Package size 1 weight
1.2101 kg
Package size 1 width
150 mm
Sales unit
1
Downloadables
No downloadable files available for this product.
Not finding what you're looking for? We're here to help!
We can assist you with technical support, quote or tailoring options for this product
Latest News & Insights
-
Discontinuation of 3-pole EVA and VKA 80–160A Switches
23.6.2025 -
Introducing the Refreshed LK10 handle: New Fresh Design, Same Trusted Performance
2.9.2024 -
KATKO Has Published Its First 'Sustainability at KATKO' Report
8.11.2024 -
KATKO KL Terminal Blocks Comply with the Requirements of the IEC TS 60947-7-5 Technical Specification
29.4.2025 -
KATKO LoadSafe Product Family – New Additions, Now Available
14.1.2025 -
Katko Products Available on EPLAN Data Portal
14.9.2023 -
KATKO Strengthens Presence in Sweden: Kim Rannanjärvi Appointed Sales Manager
28.7.2025 -
KATKO Strengthens Presence in UK: Ian Bullock Appointed Sales Director
10.11.2025 -
New Front Plate for KU 16–40A Switch Series
26.8.2025 -
Jyrki Luomi has been appointed as the Commercial Director of Katko Oy
17.9.2024 -
Product Update: Extended Cable Range for 95-Series Connectors
30.10.2025 -
The Core of Responsible and Transparent Collaboration – Partner Code of Conduct
6.2.2025
1
/
z
3