Isolating switch EMC 3x400A IP66

KET 3400 YR T7EMC 2XM63MEMC

Isolating switch EMC 3x400A IP66

Katko EMC isolators (10-1600A) are engineered to ensure reliable isolation while maintaining electromagnetic compatibility in sensitive installations. They are designed to meet the requirements of environments where electrical interference must be carefully controlled.

By combining effective shielding with durable construction, EMC isolators support stable system performance in industrial, commercial, and infrastructure applications where EMC compliance is critical.

GTIN
6419410338773
Rated operational current AC-23A 415V (A)
400
Enclosure type
Painted sheet steel
Enclosure
T7 (600 x 800 x 250 mm)
View full details

Product details and documents

Technical data

Cable entries
2 x M63 (34,0-44,0mm), metal EMC
Depth
250 mm
EMC
true
Enclosure
T7 (600 x 800 x 250 mm)
Enclosure type
Painted sheet steel
ETIM Class
EC000216
GTIN
6419410338773
Height
800 mm
IP rating
IP66
Long product name
3-pole, Yellow-red handle, Sheet steel enclosure; W600 x H800 x D250,EMC shielded, Cable entries: 2 x M63 (34,0-44,0mm), metal EMC
Max. term. torque (Nm)
30..44
Mech. endurance (no. of oper.)
10000
Net weight
31.7348 kg
Nom. values w/cable size (mm²)
240
Number of poles
3
Product type
KET 3400 YR T7EMC 2XM63MEMC
Rated breaking cap. ICN AC-23A 415V (A)
3200
Rated breaking cap. ICN AC-23A 500V (A)
3200
Rated breaking cap. ICN AC-23A 690V (A)
3200
Rated fused short-ckt current back-up fuse opt 1 (A)
400
Rated fused short-ckt current peak value (kA)
42
Rated fused short-ckt current RMS Ik opt 1 (kA)
100
Rated fused short-ckt. impulse withstand volt. Uimp (kV)
12
Rated insulation volt. Ui (V)
1000
Rated operational current AC-21A 415V (A)
400
Rated operational current AC-21A 500V (A)
400
Rated operational current AC-21A 690V (A)
400
Rated operational current AC-22A 415V (A)
400
Rated operational current AC-22A 500V (A)
400
Rated operational current AC-22A 690V (A)
400
Rated operational current AC-22B 800V (A)
400
Rated operational current AC-23A 1000V (A)
200
Rated operational current AC-23A 415V (A)
400
Rated operational current AC-23A 500V (A)
400
Rated operational current AC-23A 690V (A)
400
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 415V (kW)
200
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 500V (kW)
250
Rated oper. power 3-ph 1500rpm SQ cage motor AC-23A 690V (kW)
355
Rated short-ckt. making cap. Icm 690V (kA)
27.5
Rated short-time withstand current 1s Icw 1000V (kA)
13.5
Rated therm. current Ithe (A)
400
Rated therm. current Ith (A)
400
Short product description
Isolating switch EMC 3x400A IP66
Switch type
Load Break Switch
Technical name
3x400A 400V 200kW
Terminals bolt size (Cu mm²)
M10
Volume
120 l
Width
600 mm

No dimensional drawings available for this product.

Dimensional drawing

No dimensional drawings available for this product.

Logistical data

Package size 1
1
Package size 1 depth
250 mm
Package size 1 GTIN code
6419410341834
Package size 1 height
800 mm
Package size 1 volume
120 l
Package size 1 weight
30.9645 kg
Package size 1 width
600 mm
Sales unit
1

Downloadables

    No downloadable files available for this product.

    Not finding what you're looking for? We're here to help!

    We can assist you with technical support, quote or tailoring options for this product